Telespace Networks

Industry

Offshore and Marine

Sealed MIL-style and expanded-beam connectors, armoured fiber assemblies and drum reels for platforms, vessels, ports and coastal sites.

What fails here

The conditions your links have to survive

  1. Salt spray and corrosion

    Salt attacks plating, coupling threads and exposed metal. Shell finish and jacket choice matter as much as the optics.

  2. Water at the interface

    Rain, green water and washdown find every unsealed joint. Sealing must hold mated and with caps fitted.

  3. UV and temperature cycling

    Deck cables sit in direct sun and cool sharply at night. UV-stable, low-temperature-flexible jackets avoid cracking.

  4. Hard to reach, expensive to fix

    A failed link offshore can mean a vessel visit or a helicopter seat. Build quality and spares planning pay for themselves.

Products for offshore

What we build for offshore and marine

Rendered cutaway of an expanded beam connector showing lenses widening the light between two fibers Fiber

Expanded Beam Fiber Optic Connectors

Lens-coupled connectors that keep working in dirt, mud and rain.

  • CouplingLens, non-contact
  • MatingHermaphroditic
  • ChannelsSingle or multi
View specs
Rendered fiber optic connector assembled with its cable, showing a sealed rugged shell Fiber

MIL Circular Fiber Connector, 4 to 48 Channels

Up to 48 fibers through one rugged circular connector.

  • Channels4 to 48
  • Cable ODUp to 7.5 mm
  • ReceptacleMicro receptacle
View specs
Four ODC-style outdoor fiber connectors, two cable plugs and two square-flanged panel receptacles Fiber

ODC-Style Outdoor Fiber Connector, 2 and 4 Channel

Sealed 2 and 4 channel field connectors for towers, rail and industrial sites.

  • Channels2 or 4
  • IngressIP67
  • BodyUV and corrosion resistant
View specs
Olive backpack cable drum frame with camouflage carry straps and an empty metal drum Fiber

Harsh-Environment Cable Drums and Backpack Reels

Carry the cable on your back and pay it out by hand.

  • TypeBackpack or frame drum
  • DeploymentManual, hand crank
  • StrapsAdjustable
View specs
Reel of black armoured TPU single-mode fiber cable with LC connector breakouts hanging from the end Fiber

6-Fiber Armoured Tactical Cable Assembly

Six single-mode fibers under steel armour, in a 5.0 mm jacket.

  • Fibers6, single-mode
  • FiberG.657A bend-insensitive
  • ArmourStainless steel spiral
View specs
Black outdoor fiber cable assembly with an LC duplex breakout on one end and a round metal rugged plug on the other Fiber

Outdoor Fiber Optic Cable Assemblies

Sealed fiber jumpers for towers, poles, enclosures and field sites.

  • SealingIP67 (mated)
  • Temperature-40 to +85 °C
  • FiberSM or MM
View specs
Two MIL-DTL-38999 style circular fiber optic receptacles with multiple termini cavities and yellow fibers Fiber

MIL Circular Fiber Optic Connector

Multi-channel circular fiber connectors for vehicles, ships and airframes.

  • StyleMIL-DTL-38999 type
  • TerminiGenderless
  • Ferrule1.25 mm ceramic
View specs
Olive-drab knurled MIL circular fiber optic connector with a tethered dust cap Fiber

MIL-Aero Fiber Optic Cable Assemblies

Rugged fiber assemblies for airframes, vehicles, ships and field systems.

  • FiberSM or MM
  • Connectors38999, TFOCA-style, LC, SC, ST, FC
  • JacketPU, LSZH or fluoropolymer
View specs
Grey expanded-beam tactical fiber plug and receptacle beside a metal reel of black field cable Fiber

Tactical Expanded-Beam Fiber Cable Assemblies

Field cable that mates end to end, in mud, rain and dust.

  • ConnectorExpanded beam, hermaphroditic
  • ContactNon-contact lens interface
  • JacketPolyurethane
View specs
Exploded render of a fiber optic connector showing ferrule, body, spring and housing parts Fiber

Harting-Compatible LC Industrial Fiber Connector

LC fiber inside a sealed industrial housing for turbines, panels and plant.

  • HousingHan-type rectangular
  • Fiber connectorLC
  • FiberSM or MM
View specs
Black tactical fiber cable on a metal spool with olive rugged connectors and protective caps Fiber

Fiber Optic Harnesses and Optical Systems

Multi-branch fiber harnesses built to your drawing and tested leg by leg.

  • BuildTo drawing
  • BranchesMulti-leg breakouts
  • FiberSM or MM
View specs

Engineering notes for offshore and marine

The environment

Offshore platforms, vessels, ports and coastal sites combine nearly every threat a fiber link can face. Salt spray settles on every surface and corrodes metal. Water arrives as rain, spray, washdown and occasional immersion. Deck cables bake in tropical sun and cool quickly at night, and the whole structure vibrates with machinery, wind and sea state. Many sites are classified hazardous areas with their own rules on equipment.

Access is the hidden cost. A link that fails on a platform or a ship at sea may wait days for a technician, so the extra cost of a better connector or a spare leg is small against one call-out.

What fails

Corrosion is the slow killer: coupling nuts seize, shell plating blisters and grounding paths fail. Water ingress follows, usually at a connector that was left uncapped, a damaged boot or a gland that was never designed for submersion. Contamination at physical-contact interfaces is common because cleaning conditions on deck are poor. Mechanical damage happens where cables cross walkways, pass through cable trays with sharp edges or are pulled through glands.

What to specify

  • Connector: expanded beam where connectors are mated outdoors or in wet spaces; MIL-style circular connectors from 2 to 48 channels for sealed equipment interfaces; ODC-style field connectors for compact 2 and 4 channel links.
  • Sealing: the IP rating mated and unmated, and for IP68 the stated depth and duration.
  • Materials: shell plating or material suited to salt spray, and a jacket that is UV-stable, flexible at low temperature and, where required, low smoke zero halogen for enclosed spaces.
  • Cable: armoured construction where crush or rodents are a risk, single-mode OS2 for anything beyond short runs, fiber count with spares.
  • Deployment: drum reels for temporary or recoverable cables, panel receptacles for fixed ends, and protective caps with lanyards on every connector.
  • Testing: insertion loss per channel at the stated wavelengths, with results supplied with the assembly.

Standards that matter

IEC 60529 defines IP67 and IP68 sealing. MIL-DTL-38999 is the reference circular connector family that many marine connectors follow. Expanded-beam connectors are described in our expanded beam vs physical contact guide. LSZH jacket performance is covered by IEC 60332 (flame) and IEC 61034 (smoke). Offshore and marine projects often add class society or site-specific requirements: list them on your request and we will tell you plainly what we can and cannot meet.

From drawing to drum

Telespace builds offshore assemblies in its Mumbai workshop: cable cut and prepared, connectors terminated and sealed, every channel inspected and tested before the assembly is wound onto its drum. When the job needs a non-standard connector arrangement or a hybrid fiber and copper build, custom engineering is the place to start.

FAQ

Offshore and Marine: questions buyers ask

Which connector is best for offshore fiber links?

Where connectors are mated on deck or in wet, salty conditions, expanded-beam connectors are the safest choice because they tolerate contamination and can be rinsed and wiped. For sealed equipment interfaces, MIL-style circular connectors with suitable plating and a confirmed IP rating work well.

Is IP68 enough for a marine connector?

IP68 tells you the connector resists continuous immersion under conditions the maker states, but not for how long, how deep, or whether the rating holds unmated. For marine use, also specify plating or shell material for salt spray and a UV-stable jacket.

Can you supply cable on drums for temporary offshore work?

Yes. We build armoured or polyurethane-jacketed fiber assemblies wound onto harsh-environment drums, with connector receptacles or panel ends to suit the installation.

Request a quote

Tell us where the signal has to go in offshore.

Send a drawing, a part number or a rough description. An engineer replies within one business day with options and a quote.

Pan-India dispatch from our Mumbai workshop by courier or your nominated transporter.